Blogs
English

River Water Level Monitoring System

Continuous, unattended stage measurement for rivers, streams and gauging stations — radar level sensing with 1 mm resolution, solar power and telemetry to one cloud platform.

河流水位监测系统1

Why This System

Most monitoring programmes fail not for lack of instruments, but because the record is broken. Three gaps this system closes.

1.Manual gauge readings are expensive, inconsistent and they do not scale across a river network.

taff-gauge visits sample a moment in the day. Regulation, flood reporting and allocation need a continuous record that survives for years without an operator on site. 

2.Flood peaks rise and fall between two site visits — the record you need most is the one nobody captured.

Peak level, peak timing and recession rate are all missed by intermittent readings. Continuous logging is the only way the event itself becomes evidence you can act on.

3.Remote cross-sections have no mains power and no staff, so continuous logging looks impossible.

A radar level sensor with a solar-powered RTU runs unattended at sites that are impractical to visit weekly — which is exactly where the gaps in your record are today.

Parameters Measured

Core sensing is provided by the GX-701LD radar water level sensor. The values below are the published technical parameters for that sensor.

ParameterInstrumentRangeAccuracy
Water level (stage)GX-701LD radar water level sensor (non-contact)0–30 m / 0–70 m (model)±1–3 mm
ResolutionSame unit, no configuration change1 mm—
Rate of changeCalculated in the RTU from consecutive stage readingsConfigurable—
Water temperatureOptional, integrated with a submersible pressure sensor——
Sensor specificationValue
Range0~30 m / 0~70 m
Accuracy±1~3 mm
Resolution1 mm
Data Output4-20 mA / RS485
Power Supply12 VDC( 10 V~28 V DC)
Temperature Range-20 ℃~+70 ℃
Humidity Range0~90%
Ingress ProtectionIP67

System Architecture

The sensor outputs over RS485 or 4-20 mA. The RTU reads the value, time-stamps it and drives the uplink — readings are buffered at site and back-filled when the link returns, and threshold logic runs locally even if the network is down.

GX-701LD Radar Level Sensor

RTU (RS485 / 4-20 mA input)

4G · LoRa · NB-IoT · Satellite

Cloud Platform

Dashboards · Alarms · API

河流水位监测系统2

Recommended Configuration

A standard bill of materials for one site. Quantities scale with the number of cross-sections; we return a costed BOQ within two working days of receiving site conditions.

GX-701LD radar water level sensor

Non-contact microwave ranging; 0–30 m or 0–70 m range options; ±1–3 mm accuracy; 1 mm resolution; IP67; 12 VDC supply (10–28 V DC); -20 °C to +70 °C.

Submersible pressure level sensor(Alternative)

For sites where clearance above the water is too low to mount a radar unit.

RTU telemetry unit

Reads the sensor over RS485 (documented Modbus register map) or 4-20 mA, time-stamps and buffers readings, and drives the uplink.

Solar power kit (12 V)

Panel and battery sized to the site solar resource; autonomy target consecutive cloudy days.

Shielded signal cable

National-standard 0.5 mm² conductor is the recommended cross-section for the sensor run.

Mounting bracket / mast

Bridge pier side plate, bank-mounted pole or slope arm. No stilling well required — flow does not affect the measurement, so civil work is minimal.

Cloud platform subscription

Dashboards, multi-level alarms, reporting, exports and open interfaces for your own systems.

河流水位监测系统3
河流水位监测系统4
河流水位监测系统5

Installation & Site Conditions

Mounting position

Bridge pier side plate, bank-mounted pole or slope arm above the water surface. The sensor measures down at the water — no stilling well is required and flow has no effect on the reading.

Commissioning

IVerify the supply voltage before first power-up; confirm the measurement path is clear of obstructions; tighten the cover fully after commissioning — a loose cover is the most common cause of field failures.

Maintenance

No moving parts and no mechanical wear, so the sensing head is maintenance-free. Routine site visit interval 3 months, set per site exposure.

Power

12 VDC supply, operating range 10 V~28 V DC. Solar + battery at remote sites.

Cabling

Shielded cable, 0.5 mm² national-standard conductor recommended; route on the structure, not through the water.

Enclosure rating

IP67 — suitable for outdoor riverbank exposure.

Operating environment

-20 °C to +70 °C; 0–90% RH non-condensing.

河流水位监测系统8
河流水位监测系统6
河流水位监测系统7

Data Delivery & Platform

Live stage curves — stage plotted against time with configurable periods and export

Multi-level threshold alarms — delivered by SMS, email and app push, with escalation lists

Rate-of-change detection — derived in the RTU from consecutive readings — useful for flood onset

Scheduled and ad-hoc reports — exportable for regulators and internal review

Open interfaces — Modbus register map documented on the sensor side; API, MQTT and Modbus on the platform side

河流水位监测系统9

FAQ

Radar or pressure sensor — which one suits my site?

The GX-701LD is a non-contact radar unit mounted above the water. It suits most open channels because it never touches the water, needs no stilling well and is unaffected by flow or sediment. A submersible pressure sensor is the fallback where clearance above the surface is too low. Send a photo of the cross-section and we will recommend one.

Which range option do I need — 0–30 m or 0–70 m?

The station reports no data — what do I check first??

Why does my reading jump or fluctuate?

How long can the station run without mains power?

Professional Techincal Team
Customized Ready-to-Use Natural Disaster Monitoring & Early Warning Systems
If you want to get help immediately, please chat onile now. At the same time, you can as fill in your requirements, we will reply you in 24 hours.
Copyright © 2025 BGT Hydromet. All Rights Reserved.